DC-DC Converter PCBA Test
Test Coverage:
- Check Error Memory (Test command through CAN interface
- Set DUT in mode (Test command through CAN interface)
- Check SW-version (via CAN) ) (Compare with Flex Flow data)
- Voltage calibration (via CAN) (Test/cali by Power Supply + E-Load + DMM)
- Current calibration (via CAN) (Test/cali by Power Supply + E-Load + CT-Box)
- Check Error-Memory at the end (Test command through CAN interface)
- Mark the board with a cycle on PCB (motor with a curving pin)
Test Equipme